Government tenders in NCTPS II
61 open tenders in NCTPS II, the next closing 18 Sep 2026, 1 of them over ₹1 Cr. Updated every day.
Open all 61 in the search →Closing soonest
The 60 nearest deadlines of 61. The search above has all of them, with filters for value and deadline.
NCTPS-II MI Circle Boiler Maintenance Division Unit II Dismantling, cleaning and rectification of defective / dislocated boiler seal trough seal plates and S.S
NCTPS II M-I Circle - BM Division - Unit-II- In situ, online safety valve floating and Pressure setting of Boiler Drum, super heater, HRH and CRH safety valves
Outsourcing of Computer Operator Data Entry Operator through licensed contract for the period of one year
NCTPS II M I circle - BM Division - 600 MW - Unit II - Attending annual overhaul works of rectification of corroded, eroded and damaged Economiser hopper duct s
NCTPS II - M-I Circle - BM Dn. Unit-I ESP A,B,C D Passes -Inspection of rectification of eroded Punctured ESP EERM Floor casing plates and field internals in ES
NCTPS II M-I Circle - BM Division - Unit-I- Insitu, online safety valve floating and Pressure setting of Boiler Drum, super heater, HRH and CRH safety valves du
NCTPS II MI Circle - BM Unit-I 600 MW Boiler Conducting tube thickness survey during AOH for the year 2026-27
NCTPS II - M-I Circle BM - Unit -II Boiler - conducting tube thickness survey in first and second pass Oxide scale Thickness Measurement in Super heater, Reheat
NCTPS-II M-I Circle BM Unit II Boiler - 600 MW - Overhauling of Coal oil burner assemblies and burner tilting mechanism in corner-4 during the year 2026-27
NCTPS - II- M-I Circle MPM Unit-II Mill 2A to 2J Rectification Strengthening of existing damaged Expansion bellows in Hot air ducts Cold air ducts and rectifica
NCTPS II SE MI MPM UNIT I Mills 1A to 1J Rectification Strengthening of existing damaged Expansion bellows in Hot air ducts Cold air ducts and rectification of
NCTPS II MI MPM Unit I Reconditioning and Rectification of Multiple port outlet (MPO) and fixing of ceramic tiles during Capital Overhaul 2026-27
NCTPS II - M-I Circle BM Unit II Boiler - 600 MW - Overhauling of Coal oil burner assemblies and burner tilting mechanism in corner-3 during the year 2026-27.
NCTPS-II M-I Circle BM- Division- Unit I II Boiler 600 MW - Annual overhaul -Renewal of damaged and worn out Hastalloy seal assemblies in Guillotine Gates of Pr
NCTPS II - M-I Circle Boiler maintenance Division - Unit I II - Overhauling of Boiler fill pumps Horizontal multi stage pumpand Condensate transfer Pumps Horizo
NCTPS-II M-I Circle BM Division - Unit II - Annual overhaul of hanger supports of Main steam line, Cold Re-heater line, Hot Re-heater line, Inlet feed line, Pen
NCTPS - II- M-I Circle MPM Unit II Overhauling of suction discharge dampers, suction butterfly valve, rectification replacement of rubber bellows, strengthening
NCTPS - II- M-I Circle MPM Dn. Unit II Mill 2A to 2J Replacement of damaged gasket after dismantling of special 414 couplings, aligning, reassembling and normal
NCTPS II - MI - MPM-Unit II - Mills 2A to 2J - Fixing of ceramic tiles in the inner cone, filling of ceramic putty in Multiple Port Outlet, Mill Discharge Valve
NCTPS II - MI Circle - BM - Unit-II - Annual overhaul of Rectification and replacement of corroded, eroded and damaged expansion joints in Primary Secondary air
NCTPS II Mech. I Circle Common Auxiliaries RODM Overhauling of D M water storage tanks 3_4 and Inspection cleaning of Dm water storage tanks and Condensate Stor
NCTPS - II- M-I Circle MPM Division AC Plant AOH 2026-27-Units I II Overhauling for AHU assembly of PHB , service building ESP I II AHUs by dismantling AHU asse
NCTPS-II-M-I-CA-CWPH-Unit -II- Cleaning of condenser cooling water inlet lines of Unit-II from manhole-4 to condenser inlet of both A B pass during the annual o
NCTPS-II-M-I Circle-CA-CWPH- Unit-II- Rectification of worn-out oversized bearing housing of element column pipes, dismantling of worn out wear ring of pump cas
NCTPS-II-M-I-CA-CWPH-Unit-II-Dismantling of manholes cum air release valves to facilitate cleaning of cooling water inlet lines from CWPs 2A to 2Fs discharge el
NCTPS-II-M-I-CA-CWPH-Unit II- Cleaning of condenser cooling water inlet lines of Unit-II from manhole-2 to manhole-3 of both A B pass during the annual overhaul
NCTPS - II- M-I Circle MPM Unit-I Mill 1A to 1J Replacement/Rectification of Hot air gate, Hot air dampers and its power cylinders, Cold air gates, Cold air dam
NCTPS-II-M-I-CA-CWPH-Unit-II-Cleaning of condenser cooling water pipe line of Unit-II from cooling water pumps 2A to 2F discharge elbow to manhole-2 of both A B
NCTPS - II- M-I Circle MPM Unit-I - Overhauling of mill feeder outlet gate and its power cylinder during Capital overhauling of 2026-27
NCTPS -II -M-I circle- Common Auxiliaries Division- Overhauling of CWPH. RWPH, RODM, ETP water system LT switchgears during AOH 26-27
NCTPS-II -M-I circle- Common Auxiliaries Division- Servicing of electrolyzers cells in stream-C in Electro Chlorination Plant
NCTPS-II-M-I-CAD Electrical works Overhauling of LV bus ducts in CWPH, RWPH WATER SYSTEM Switchgear Annexures during AOH 2026-27.
NCTPS-II-M-I Circle-CA-CWPH- Unit-II- Rectification of worn-out/ oversized bearing housing of element column pipes, dismantling of worn out wear ring of pump ca
Overhauling of Travelling water screen 2B and renewal replacement of defective parts with new or reconditioned spares after minor rectification, if necessary an
NCTPS-II-M-I-CA-CWPH-Unit-II Overhauling of Travelling water screen 2E and renewal replacement of defective parts with new or reconditioned spares after minor r
Overhauling of Travelling water screen 2F and renewal replacement of defective parts with new or reconditioned spares after minor rectification, if necessary an
NCTPS-II-M-I Circle-CA-CWPH- Unit-II-Inspection of internals, attending defects by dismantling the CWP 2D internal parts, rectifying and replacing the damaged p
NCTPS-II-M-I Circle-CA-CWPH- Unit-II-Inspection of internals, attending defects by dismantling the CWP 2E internal parts, rectifying and replacing the damaged p
NCTPS II Mechanical I Circle Common Auxiliaries S.Dn. II Unit II AOH Overhauling of DM water transfer pump 2A 2B (Split casing two stage horizontal centrifugal
NCTPS-II M I Circle Boiler maintenance Division Unit-II Providing platform extension work in boiler LHS walkway ladder area at 9 Mtr elevation to facilitate to
NCTPS-II - M I Circle BM Unit-II Annual overhaul of PA Fan 2A 2B during the year 2026-27
NCTPS II M-I Circle - BM - Unit-II - AOH 2026-27-Replacement of the severely eroded and damaged A1, A2, B1 B2 stream Splitter assembly in flue gas duct at ESP i
NCTPS II M-I Circle - BM - Unit-II - AOH 2026-27-Replacement of the severely eroded and damaged C1, C2, D1 D2 stream Splitter assembly in flue gas duct at ESP i
NCTPS-II - M-I Circle- BM Unit-II AOH of FD Fan 2A 2B for the year 2026-27
NCTPS II MI Circle BM-III - Unit-II - Annual overhaul of ID fan 2A 2B during the year 2026-27
NCTPS II MI Circle - BM Dn.- Unit-II - ESP A,B,C, D Passes Inspection of rectification of eroded,Punctured ESP EERM Floor casing plates and field internals in E
NCTPS II MI Circle - BM Unit-II - Renewal of damaged top suction hood area of PA Fan 2A 2B during the year 2026-27
NCTPS II M-I Circle- BM Unit-II Annual overhaul of Replacement of severely corroded and damaged discharge ducts of PA fans and FD fans during the year 2026-27
NCTPS II M I Circle BM Division Unit-II Boiler 600 MW Providing steps from 66mtr EL to 43 mtr EL in Boiler rear side for ease of maintenance and free movement o
NCTPS II MI Circle - BM Dn.- Unit-II - Annual Overhaul of Flue Gas Duct - APH hopper area and ESP outlet to Chimney Inlet duct - Inspection, rectification of er
NCTPS II MI Circle - BM - Unit-II - AOH 2026-27 -Removal of accumulated ash from ESP outlet duct to Chimney Inlet
NCTPS II M-I Circle- BM - Unit-II Annual overhaul of Rectification of eroded and punctured duct portion by patch welding and metal filling of welding joints in
NCTPS-II-M-I Circle-CA-CWPH- Unit-II- TWS 2E-Inspection of Travelling water screens 2E boot section assembly by complete dismantling of basket trays chain link
NCTPS-II-M-I Circle-CA-CWPH- Unit-II- TWS 2D-Inspection of Travelling water screens 2D boot section assembly by complete dismantling of basket trays chain link
NCTPS-II-M-I-CA-CWPH-Unit-II-Dewatering to facilitate cleaning of cooling water inlet lines from CWPs 2A to 2Fs discharge elbow to condenser inlet, cleaning of
NCTPS-II-M-I-Circle-CA-CWPH-Unit-II-Dismantling of manhole cum butterfly valves, de-watering the condenser cooling water outlet pipelines of both A B passes to
Level indicator for DM storage tanks in RODM plant
NCTPS-II - M-I-MPM-Unit-II - Corner-4 - Overhauling of worn-out fuel inlet elbows along with shut off gates, special bends and orifice by dismantling lowering t
NCTPS-II SE MI MPM Unit II Mill 2A to 2J Overhaul of lube oil coolers, cleaning removing of dust particles, sediments from lube oil tank of mills during Annual
NCTPS-II - M-I Circle CAD -NCTPS-II - M-I Circle - CAD - Dismantling of CWP motor, Inspection, Removal of coolers, cleaning of coolers, on-site balancing of fan
Departments in this list
Work types in this list
Portals in this list
Details here are copied from the portal that published each tender. Always confirm the deadline and documents on that portal before bidding.